Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study
作者:Yu IJ, Kook YA, Sung SJ, Lee KJ, Chun YS, Mo SS · 发表于:European journal of orthodontics · 年份:2014 · DOI:10.1093/ejo/cjr130
The purposes of this study were to mechanically evaluate distalization modalities through the application of skeletal anchorage using finite element analysis. Base models were constructed from commercial teeth models. A finite element model was created and three treatment modalities were modified to make 10 models. Modalities 1 and 2 placed mini-implants in the buccal side, and modality 3 placed a plate on the palatal side. Distalization with the palatal plate in modality 3 showed bodily molar movement and insignificant displacement of the incisors. Placing mini-implants on the buccal side in modalities 1 and 2 caused the first molar to be distally tipped and extruded, while the incisors were labially flared and intruded. Distalization with the palatal plate rather than mini-implants on the buccal side provided bodily molar movement without tipping or extrusion. It is recommended to use our findings as a clinical guide for the application of skeletal anchorage devices for molar distalization.