Analysis of temperature field evolution in ground freezing construction of twin tunnels in a coastal urban area
作者:Taiqiang Ye, Jun Hu, Jie Zhou, Huajing Gan, Lei Huang, Xinmin Shang · 发表于:Scientific Reports · 年份:2025 · DOI:10.1038/s41598-025-14000-4 · 被引用次数:3 · 研究领域:Climate change and permafrost、Underground infrastructure and sustainability、Methane Hydrates and Related Phenomena
In the field of underground engineering, the artificial ground freezing method has emerged as a highly effective technique due to its excellent impermeability, controllability, and minimal environmental impact. This method is particularly advantageous in complex geological and urban settings, making it widely used in tunnel construction under challenging conditions. However, in the case of twin-tunnel (or two-lane tunnel) projects, accurately predicting the temperature field during the freezing process remains a critical challenge. One of the key issues lies in the uncertainty of excavation rates, which significantly affects the development and control of the frozen wall. This paper establishes a three-dimensional water-heat coupling model based on the actual project of an underground two-lane tunnel in a city near the sea. Through numerical simulations, the model analyzes and investigates the temperature field maps, effective permafrost curtain thickness, and the cooling law of the two primary surface paths. The findings indicate that the development of effective permafrost curtain thickness is significantly influenced by seepage. The upstream side of the left tunnel experiences the greatest impact at 45°, 90°, and 135°, with the downstream side of the right tunnel showing less influence in five directions. The development trend of effective permafrost curtain thickness in the 90° direction of the left tunnel is opposite to that of the right tunnel, with a difference of 1.73...