Excellent Results With Low Reoperation Rates After Fixation of Patella Fractures With a New Anatomically Contoured Plating System
作者:M. Kareem Shaath, Brendan Page, Bader A. Nasir, Griffin R. Rechter, Astrid Casin, Jonathan P. Yawman, Elizabeth Jacobs, Joshua R. Langford, George J. Haidukewych · 发表于:Journal of Orthopaedic Trauma · 年份:2025 · DOI:10.1097/bot.0000000000003025 · 被引用次数:7 · 研究领域:Lower Extremity Biomechanics and Pathologies、Sports injuries and prevention、Knee injuries and reconstruction techniques
OBJECTIVES: To assess the clinical and radiographic outcomes of a consecutive series of patellar fractures treated utilizing an anatomically contoured variable-angle patellar plating system (PPS) (Synthes; Paoli, PA). METHODS: Design: Retrospective chart review. SETTING: Single, academic, Level-1 Trauma center. PATIENT SELECTION CRITERIA: All adult patients who underwent fixation of a patellar fracture (AO/OTA 34) with the PPS between 2021 and 2024 with a minimum follow-up of 3 months. Post-operatively, full extension was maintained for six weeks. OUTCOME MEASURES AND COMPARISONS: The primary outcome was fixation failure. Secondary outcomes included range of motion (ROM) at final follow-up, knee pain due to symptomatic implants, infection, and reoperation. Deep infection was defined as a return to the operating room for irrigation and debridement. RESULTS: There was a total of 61 patients with a mean age of 54 years (19-92 years). The cohort consisted of 32 females (52%) with a mean BMI of 27 kg/m2 (18-42 kg/m2). Fifteen patients (25%) had diabetes and 16 patients were smokers (26%). The average follow-up was 7 months (range 3 - 26 months).There were 2 34A1 fractures, 1 34B1 fracture, 16 34C1 fractures, 10 34C2 fractures, and 32 34C3 fractures. There were 6 open fractures (1%), 2 type II and 4 type IIIA.There were 54 (89%) patients who achieved uneventful healing. Seven patients (11%) experienced a postoperative complication. One patient developed a superficial wound infectio...