Surface Cleaning with a Microfiber Cloth and Water followed by Ultraviolet-C Light Exposure Achieves Non-Inferior Disinfection of a Pathogenic Staphylococcus aureus Strain versus Use of Germicidal Wipes.
作者:Stephanie Gibbons, Franklin Dexter, Randy W. Loftus, Brendan T. Wanta, Carmen T Brindeiro, Soyun M Hwang, Jonathan E. Charnin · 发表于:Cureus · 年份:2024 · DOI:10.7759/cureus.65963 · 被引用次数:5 · 研究领域:Infection Control in Healthcare、Medical Device Sterilization and Disinfection、Antimicrobial agents and applications
Background: We hypothesized that ultraviolet-C (UV-C) irradiation (Surfacide, Waukesha, WI) following use of microfiber cloths (Sanny Shop LLC, Longmont, CO) soaked in water would be noninferior to surface disinfection wipes containing a quaternary ammonium compound and alcohol (PDI Healthcare, Woodcliff Lake, NJ) for the pathogenic Staphylococcus aureus (S. aureus) sequence type 5 (ST5). Methods: This was a randomized laboratory study of disinfection approaches for S. aureus ST5. A total of 270 polycarbonate slides loaded with ST5 were prepared for the standard surface disinfection group (N=18) and water-soaked microfiber cloths and UV-C treatment group (N=144), along with positive and negative microbiological controls. Results: All 18 samples of S. aureus ST5 bacteria treated with standard chemical wipes showed complete disinfection (colony forming units (CFU) = 0). All 144 treatments with water-soaked microfiber wipes followed by UV-C exposure showed complete disinfection (CFU =0) regardless of soiling, height from the floor, or orientation to the emitters. The upper 95% exact one-sided confidence limit for any CFU >0 was 2.1%. Discussion: These data affirm our hypothesis that surface wiping with a damp cloth followed by triangular UV-C irradiation delivery is noninferior to surface disinfection for S. aureus ST5 using germicidal wipes, even when UV-C is compromised by height from the floor and orientation to the emitters and surface disinfection is targeted. Conclusion...