Performance evaluation of a hydrogen-fired combined cycle with water recovery
作者:Tingting Wei, Zhenchao Hu, Xingyu Tang, Huisheng Zhang · 发表于:Case Studies in Thermal Engineering · 年份:2023 · DOI:10.1016/j.csite.2023.102863 · 被引用次数:12 · 研究领域:Hybrid Renewable Energy Systems、Carbon Dioxide Capture Technologies、Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Hydrogen can alleviate the increasing environmental pollution and has good development prospects in power generation due to its high calorific value and low environmental impact. The previously designed hydrogen-fired combined cycle ignored water recycling, which led to an inefficient application of hydrogen and the wastage of water. This paper proposes the concept of a hydrogen-fired combined cycle with water recovery to reuse the condensed water as an industrial heat supply. It was applied to an F-class combined cycle power plant. The results demonstrate that the efficiency of hydrogen-fired combined cycles with and without water recovery increased by 1.92% and 1.35%, respectively, compared to that of the natural-gas-fired combined cycle under full working conditions. In addition, an economic comparison of the three cycles was conducted. The levelized cost of energy of the hydrogen-fired combined cycle with water recovery will be 52.22% lower than that of the natural-gas-fired combined cycle in 2050. This comparative study suggested that water recovery supplementation could improve the gas turbine efficiency. The proposed hydrogen-fired combined cycle with water recovery would provide both environmental and economic benefits.