Scholay

学术搜索 · AI 审稿 · LaTeX 协作

A Coil Constant Calibration Method Based on the Phase-Frequency Response of Alkali Atomic Magnetometer

作者:Han Yao, Danyue Ma, Junpeng Zhao, Jixi Lu, Ming Ding · 发表于:Photonic Sensors · 年份:2019 · DOI:10.1007/s13320-019-0530-4 · 被引用次数:9 · 研究领域:Atomic and Subatomic Physics Research、Quantum optics and atomic interactions、Advanced Frequency and Time Standards

We propose an in-situ method to calibrate the coil constants of the optical atomic magnetometer. This method is based on measuring the Larmor precession of spin polarized alkali metal atoms and has been demonstrated on a K-Rb hybrid atomic magnetometer. Oscillation fields of different frequencies are swept on the transverse coil. By extracting the resonance frequency through phase-frequency analysis of electron spin projection, the coil constants are calibrated to be 323.1 ± 0.28 nT/mA, 108 ± 0.04 nT/Ma, and 185.8 ± 1.03 nT/mA along the X , Y , and Z directions, respectively.