Mean Tip-Apex Distance In Lag Screw Cut-Out After Dynamic Hip Screw Fixation Of Hip Fracture.
作者:Muhammad Shabir, Muhammad Inam, Abdus Saboor Awan, Faisal Kamran, Nehal Ahmad · 发表于:PubMed · 年份:2019 · 被引用次数:1 · 研究领域:Hip and Femur Fractures、Pharmacological Effects and Toxicity Studies、Bone fractures and treatments
BACKGROUND: To determine mean tip-apex distance after Dynamic Hip Screw fixation of intertrochanteric fracture. METHODS: This descriptive cross-sectional study was conducted in the Department of Orthopaedics, Hayatabad Medical Complex, Peshawar from October 2015 to September 2016 on a total 285 patients. RESULTS: A total of 285 patients were observed. Status of TAD among 285 patients was analysed as 171 (60%) patients had TAD ranged 15 mm to 20 mm, 91(32%) patients had TAD ranged 21 mm to 25 mm, 23 (8%) patients had TAD ranged >25mm. Mean TAD was 18 mm with SD±7.45. Eight percent patients had screw cut out while 92% patients didn't had screw cut out. CONCLUSIONS: To avoid lag screw cut out in dynamic hip screw for intertrochanteric fracture of hip the Tip apex distance must be accurate otherwise there will be cut out of lag screw.