Electromembrane extraction and preconcentration of carbendazim and thiabendazole in water samples before capillary electrophoresis analysis

作者:Amilton Moreira Oliveira, Hugo Campos Loureiro, Francielly Fernanda Souza de Jesus, Dosil Pereira de Jesus · 发表于:Journal of Separation Science · 年份:2017 · DOI:10.1002/jssc.201601305 · 被引用次数:42 · 研究领域:Analytical chemistry methods development、Microfluidic and Capillary Electrophoresis Applications、Electrochemical sensors and biosensors

Electromembrane extraction using a polypropylene hollow fiber impregnated with 1-ethyl-2-nitrobenzene was evaluated for the extraction and preconcentration of the fungicides thiabendazole and carbendazim from water samples before capillary electrophoresis analysis. The composition of the supported liquid membrane, the HCl concentration in the acceptor solution, and the stirring rate (of the donor solution) were optimized using the one-variable-at-a-time method. In contrast, a face-centered central composition design was used for optimization of voltage, extraction time, and concentration of HCl in the donor solution. After optimization, electromembrane extraction provided enrichment factors of 50 and 26 for thiabendazole and carbendazim that allowed us to achieve limits of detection of 1.1 and 2.3 μg/L, respectively. Repeatability (intraday precision) expressed as the relative standard deviation varied from 2.5 to 2.8%, while the interday precision ranged from 3.1 to 3.3%. The proposed method was applied for analysis of samples of tap and river water, and acceptable precision and accuracy were attained.