[Application of vacuum-assisted venous drainage technology in minimally invasive cardiac surgery].
作者:Shi Cheng, Tianxiang Gu, Zongyi Xiu, WU Li-min, Rui Gao, Ya Gao · 发表于:PubMed · 年份:2011 · 被引用次数:4 · 研究领域:Cardiac and Coronary Surgery Techniques、Pleural and Pulmonary Diseases、Medical and Biological Ozone Research
OBJECTIVE: To summarize the method and experience of cardiopulmonary bypass (CPB) with vacuum-assisted venous drainage technology (VAVD) in the minimally invasive cardiac surgery (MICS). METHODS: 35 cases of patients undergoing MICS were achieved femoral arterial cannula and femoral venous cannula. During the course of the CPB, we used the VAVD technology. At the same time, we selected 35 cases as control group.The time of the CPB, mechanical ventilation and ICU, and the amount of the urine, blood products, and chest drainage were recorded. RESULTS: The time of mechanical ventilation and ICU staying, the volume of the blood products and the volume drainage within 48 h postoperatively in the MICS group were significantly shorter and less than that in control group (P < 0.05). CONCLUSION: The use of VAVD in the MICS can increase the vena cava drainage effectively, and ensure the surgery safe and successful.