Scholay

学术搜索 · AI 审稿 · LaTeX 协作

Effects of Concrete Strength and Reinforcing Clear Distance on the Damage of Reinforced Concrete Slabs Subjected to Contact Detonations

作者:Masahiro Morishita, Hideaki Tanaka, Tomohiro Ando, Hiroyuki Hagiya · 发表于:Concrete Research and Technology · 年份:2004 · DOI:10.3151/crt1990.15.2_89 · 被引用次数:66 · 研究领域:Structural Response to Dynamic Loads、Structural Behavior of Reinforced Concrete

In this study, the effects of concrete strength and reinforcing clear distance on the damage of reinforced concrete (RC) slabs subjected to contact detonations have been experimentally investigated to establish the design and damage estimation methods of RC shelters. The main results obtained are as follows : 1) The concrete strength and the clear distance don't affect cratering and spalling significantly. 2) The dimensions of the crater and spall are relatively well predicted with the authors' method for the RC slabs with the ultra high strength concrete and much longer reinforcing clear distance than diameters of the crater and spall. 3) The surface and inside cracking tends to occur more remarkably with higher strength concrete and longer reinforcing clear distance.