Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards
作者:Kees Booij, Hedwig M. Sleiderink, Foppe Smedes · 发表于:Environmental Toxicology and Chemistry · 年份:1998 · DOI:10.1002/etc.5620170707 · 被引用次数:298 · 研究领域:Recycling and Waste Management Techniques、Microplastics and Plastic Pollution
Abstract Organic contaminant exchange kinetics between semipermeable membrane devices (SPMDs) and water were studied in two suspensions of estuarine and marine sediments under conditions of high and low turbulence over a period of 56 d. Prior to exposure, the SPMDs were spiked with a number of exposure standards not occurring in the environment. The release rate of these compounds was used as an independent measure of the exchange kinetics between the SPMD and water. The uptake rates of chlorobenzenes, polychlorinated biphenyls, (PCBs) and polycyclic aromatic hydrocarbons (PAHs) were lower by a factor of three under conditions of low turbulence. For compounds with a log octanol–water partition coefficient (Kow) > 5.5 the uptake rate was constant during the entire period. Within each compound class, uptake rate constants correlated well with log Kow. The uptake rate constants of PAHs were lower than those of PCBs and chlorobenzenes by a factor of 10, but these estimates probably are artificially low due to an overestimation of the aqueous PAH concentrations. Release rate constants of the exposure standards fell within the range of the uptake rate constants of chlorobenzenes and PCBs, although with poor precision. Suggestions for improving the measurement of exchange rate constants of exposure standards are presented. The role of triolein in the exchange kinetics is shown to be minor.