Silver-Coated Endotracheal Tubes and Incidence of Ventilator-Associated Pneumonia
作者:Marin H. Kollef · 发表于:JAMA · 年份:2008 · DOI:10.1001/jama.300.7.805 · 被引用次数:483 · 研究领域:Nosocomial Infections in ICU、Respiratory Support and Mechanisms、Infection Control in Healthcare
CONTEXT: Ventilator-associated pneumonia (VAP) causes substantial morbidity. A silver-coated endotracheal tube has been designed to reduce VAP incidence by preventing bacterial colonization and biofilm formation. OBJECTIVE: To determine whether a silver-coated endotracheal tube would reduce the incidence of microbiologically confirmed VAP. DESIGN, SETTING, AND PARTICIPANTS: Prospective, randomized, single-blind, controlled study conducted in 54 centers in North America. A total of 9417 adult patients (> or = 18 years) were screened between 2002 and 2006. A total of 2003 patients expected to require mechanical ventilation for 24 hours or longer were randomized. INTERVENTION: Patients were assigned to undergo intubation with 1 of 2 high-volume, low-pressure endotracheal tubes, similar except for a silver coating on the experimental tube. MAIN OUTCOME MEASURES: Primary outcome was VAP incidence based on quantitative bronchoalveolar lavage fluid culture with 10(4) colony-forming units/mL or greater in patients intubated for 24 hours or longer. Other outcomes were VAP incidence in all intubated patients, time to VAP onset, length of intubation and duration of intensive care unit and hospital stay, mortality, and adverse events. RESULTS: Among patients intubated for 24 hours or longer, rates of microbiologically confirmed VAP were 4.8% (37/766 patients; 95% confidence interval [CI], 3.4%-6.6%) in the group receiving the silver-coated tube and 7.5% (56/743; 95% CI, 5.7%-9.7%) (P = ....