Scholay

学术搜索 · AI 审稿 · LaTeX 协作

Establishing the Reliability and Validity of Measurements of Walking Time Using the Emory Functional Ambulation Profile

作者:Steven L. Wolf, Pamela A. Catlin, Katherine Gage, Karen Gurucharri, Renee L. Robertson, Kathleen Stephen · 发表于:Physical Therapy · 年份:1999 · DOI:10.1093/ptj/79.12.1122 · 被引用次数:265 · 研究领域:Balance, Gait, and Falls Prevention、Stroke Rehabilitation and Recovery、Assistive Technology in Communication and Mobility

BACKGROUND AND PURPOSE: The Emory Functional Ambulation Profile (E-FAP) measures time to walk in different environments and accounts for use of assistive devices. This study assessed the reliability and validity of walking time measurements using these components. SUBJECTS: Twenty-eight subjects who had strokes and 28 subjects without impairment were recruited. METHODS: The E-FAP, Berg Balance Test, Functional Reach Test, and Timed 10-Meter Walk Test were administered in random order during a single data collection session. RESULTS: Interrater reliability for the total E-FAP was > or = .997. Subjects without impairment performed better on all 4 tests than did subjects who had strokes. Increased times on the E-FAP correlated with poor performance on the Berg Balance Test and slow gait speeds on the Timed 10-Meter Walk Test in the subjects who had strokes. The E-FAP scores and the Functional Reach Test scores were not correlated. CONCLUSION AND DISCUSSION: The E-FAP can be administered easily and inexpensively. Because the E-FAP scores differentiated subject groups and correlated with known measures of function, the E-FAP may be a clinically useful measure of ambulation.