Measurement of the Interstitial Pressure in Subcutaneous Tissue in Dogs

作者:H. J. Ladegaard‐Pedersen · 发表于:Circulation Research · 年份:1970 · DOI:10.1161/01.res.26.6.765 · 被引用次数:31 · 研究领域:Biomedical and Chemical Research、Non-Invasive Vital Sign Monitoring、Veterinary Pharmacology and Anesthesia

A probe consisting of a cotton thread fitted inside a 15-cm Teflon tube with an inner diameter of 0.8 mm and connected to a transducer was used to measure the interstitial pressure in the subcutaneous tissue in six anesthetized dogs. The measurements were reproducible with a standard deviation of ±0.64 mm Hg. In six dogs the mean pressure in the subcutaneous tissue of the thorax was --2.74 mm Hg (range --3.25 to --1.99 mm Hg). After hemorrhage and dextran (10%) infusion, the mean pressure decreased by 1.70 mm Hg. After infusion of lactated Ringer's solution, the pressure increased to the control values.