A single plasma sample method for estimation of the glomerular filtration rate in infants and children using iohexol, II: establishment of the optimal plasma sampling time and a comparison with the99Tcm-DTPA method
作者:Gunnar Stake, E. Monn, Kjell Rootwelt, T. Monclairt · 发表于:Scandinavian Journal of Clinical and Laboratory Investigation · 年份:1991 · DOI:10.1080/00365519109091625 · 被引用次数:29 · 研究领域:Dialysis and Renal Disease Management、Acute Kidney Injury Research、Chronic Kidney Disease and Diabetes
The glomerular filtration rate (GFR) can be determined from the plasma disappearance rate of the non-ionic contrast medium iohexol. A preceding study established the empirical formulae enabling the development of a single plasma sample method for estimation of GFR in infants and children. In the present study the validity of these empirical formulae was confirmed in examinations in 143 patients. The results of the single plasma sample method were similar to those of a standard 99Tcm-DTPA method, and also with those of a two plasma sample iohexol method. Evaluation of the results obtained with plasma sampling 1 h, 2 h, 3 h and 4 h after the injection of the contrast medium showed that the optimal sampling time was about 3 h after the injection.