Scholay

学术搜索 · AI 审稿 · LaTeX 协作

Opportunistic Screening for Osteoporosis Using Abdominal Computed Tomography Scans Obtained for Other Indications

作者:Perry J. Pickhardt, B. Dustin Pooler, Travis Lauder, Alejandro Muñoz del Río, Richard J. Bruce, Neil Binkley · 发表于:Annals of Internal Medicine · 年份:2013 · DOI:10.7326/0003-4819-158-8-201304160-00003 · 被引用次数:951 · 研究领域:Bone health and osteoporosis research、Dental Radiography and Imaging、Parathyroid Disorders and Treatments

BACKGROUND: Osteoporosis is a prevalent but underdiagnosed condition. OBJECTIVE: To evaluate computed tomography (CT)-derived bone mineral density (BMD) assessment compared with dual-energy x-ray absorptiometry (DXA) measures for identifying osteoporosis by using CT scans performed for other clinical indications. DESIGN: Cross-sectional study. SETTING: Single academic health center. PATIENTS: 1867 adults undergoing CT and DXA (n = 2067 pairs) within a 6-month period over 10 years. MEASUREMENTS: CT-attenuation values (in Hounsfield units [HU]) of trabecular bone between the T12 and L5 vertebral levels, with an emphasis on L1 measures (study test); DXA BMD measures (reference standard). Sagittal CT images assessed for moderate-to-severe vertebral fractures. RESULTS: CT-attenuation values were significantly lower at all vertebral levels for patients with DXA-defined osteoporosis (P < 0.001). An L1 CT-attenuation threshold of 160 HU or less was 90% sensitive and a threshold of 110 HU was more than 90% specific for distinguishing osteoporosis from osteopenia and normal BMD. Positive predictive values for osteoporosis were 68% or greater at L1 CT-attenuation thresholds less than 100 HU; negative predictive values were 99% at thresholds greater than 200 HU. Among 119 patients with at least 1 moderate-to-severe vertebral fracture, 62 (52.1%) had nonosteoporotic T-scores (DXA false-negative results), and most (97%) had L1 or mean T12 to L5 vertebral attenuation of 145 HU or less. Simi...